Hotpoint SX1046LPX Service Information page 40

Mono control electronic multifunction pyrolytic built in single ovens with led door lighting
Table of Contents

Advertisement

Indesit
Company
AUTO TEST
Start with the oven off and the oven door closed.
Turn '+', turn '-', turn '+'.
Press and hold the 'clock' key for 5 seconds (a beep will sound to confirm the selection).
Press 'Start' (a beep will sound to confirm the selection.
Load Activation Sequence:
1. Indicator lamps light up for the duration of the Auto Test sequence.
2. Oven PTC probes and main NTC PCB checked.
3. For 5 seconds; Tangential Fan ON and door blocked (where there is a door lock).
4. For 5 seconds; Tangential Fan ON, Spit Roast (where present) and door lock released (where
present).
5. For 15 seconds; Circular Heating Element ON, Motor Fan ON, Spit Roast ON (where present).
6. For 15 seconds; Grill Heating Element ON, Motor Fan ON, Spit Roast ON (where present).
7. END
NOTE: - If there is a last fault, it will be displayed for the first 20 seconds before the Auto Test
sequence commences. If there is no last fault, the sequence will start immediately.