FAULT CODES
FAULT
SUBCODE
71h
72h
73h
74h
75h
76h
F24
81h
82h
83h
84h
85h
86h
01
F27
02
Service Manual UK
DESCRIPTION
Tangential fan in diode mode.
Tangential fan short circuited or
disconnected.
Tangential fan circuit open.
Tangential fan FB failure.
Tangential fan general failure.
Tangential fan in diode mode +
master relay jammed.
Circular fan in diode mode.
Circular fan short circuited or dis-
connected.
Circular fan circuit open.
Circular fan FB failure.
Circular fan general failure.
Circular fan in diode mode + master
relay jammed.
Function selector short circuited.
Function selector circuit open.
38 of 49
CHECKS
1 Check that the tangential fan is working properly.
2 Check that the motor fan is working properly.
3 Check connectors on component and main PCB
sides.
4 Check the state of cables on both fans.
5 Replace the Main PCB.
1 Check connectors on component and board
sides.
2 Check the state of cables.
3 Replace function selector.
4 Replace the Main PCB.