Operating Problems During Normal Operation
Problem
Area cannot be disarmed. In-
termittent signal is sounded
immediately after the system
status is displayed on the
reader.
Area cannot be disarmed. In-
termittent signal sounds for
approx 15 seconds after dis-
arming was requested (=
green LED flashes).
Area cannot be disarmed. In-
termittent signal sounds for
approx 15 seconds after dis-
arming was requested (=
green LED flashes).
Door will not open despite
correct disarming procedure.
Intermittent signal sounds
during code entry.
Intermittent signal sounds af-
ter a code is entered.
The "Change code" function
cannot be initiated from the
code keypad.
Door opener not activated.
Possible cause(s)
User not authorized to arm the a-
rea.
User temporarily unauthorized to
arm the area because he belongs
to a specific time group.
In the case of multiple detection
areas: arming sequence not ad-
hered to.
Additional coded arming device
(e.g. timer locks) preventing sys-
tem from disarming.
No code entered.
The "
" key was not pressed af-
ter the code was entered.
Bolt is stuck (door could be slightly
warped).
You are not intended to enter co-
des in this state.
Incorrect code entered.
Fewer than 6 digits entered.
For NZ 300 LSN: 4-digit default
code not yet extended to 6 digits.
The "Same code for all users" set-
ting has been programmed.
Lockable code keypad: The "+"
key on the keypad has not been
activated.
Detection area is armed.
Door is locked.
Magnetic contact on the SmartKey
door is open.
User temporarily unauthorized to
arm the area because he belongs
to a specific time group.
41
Fault Elimination
Elimination
Repeat the arming process after re-
moving any of the possible causes of
errors.
Repeat the arming process after re-
moving any of the possible causes of
errors.
Repeat the arming process after re-
moving any of the possible causes of
errors.
Gently jolt the door, then arm and di-
sarm the system. If this is unsuccess-
ful the door will have to be pus-
hed/pulled open with force (prede-
termined breaking point in the SPE
blocking element will break, the door
remains undamaged).
Consult your security manager.
Check possible causes of error or in-
form your security manager.
Deactivate the setting in program-
ming.
Insert bridge LF1/LF2 on the keypad
circuit board.
Repeat door opener activation, taking
the possible causes of error into con-
sideration.