42 MultiWave Control System Installation Guide
Connection for Pentair
Remove power.
1.
Connect two #14 gauge wires minimum, with an insulation rating of 105°C, to terminals 8
2.
and 9 on the PE653 (or to the Heater #1 or
Heater #2 hookup when using P5043ME).
Route the wires through the low voltage
3.
knockout in the PE653 enclosure.
Make sure that the Low Voltage Divider is in
4.
place.
Remove the heater service door.
5.
Separate the black wires (common) from
6.
each other.
Connect the wires from receiver (or
7.
expansion module) to the two black wires on
the heater. See Figure 6-6.
Do not disconnect heater's high limit or
8.
pressure switches.
Turn the heater toggle switch on, and the
9.
heater thermostat(s) to max.
When connecting an Intermatic Control
10.
System to a Pentair Heater, Pentair requires
that you install the low voltage thermostat
wires in a conduit separate from ANY line
voltage wires.
Replace service door.
11.
Re-apply power.
12.
Heaters
®
www.intermatic.com
VIO
BLK
BLK
RED
VIO
BLK
BLK
RED
Figure 6-6. Typical wiring connections for Pentair Heaters.
Wires from PE653
(or P5043ME)