Scv3000 And Scv3020 And Two Scv300 And Scv320 Expansion Enclosures - Dell SCv3000 Deployment Manual

Hide thumbs Also See for SCv3000:
Table of Contents

Advertisement

SCv3000 and SCv3020 and Two SCv300 and SCv320
Expansion Enclosures
This figure shows an SCv3000 and SCv3020 storage system cabled to two SCv300 and SCv320 expansion enclosures.
Figure 46. SCv3000 and SCv3020 and Two SCv300 and SCv320 Expansion Enclosures
1
Storage system
3
Storage controller 2
5
Expansion enclosure 2
The following table describes the back-end SAS connections from an SCv3000 and SCv3020 storage system to two SCv300 and SCv320
expansion enclosures.
Table 3. SCv3000 and SCv3020 Connected to Two SCv300 and SCv320 Expansion Enclosures
Path
Chain 1: Side A (orange)
Chain 1: Side B (blue)
Connections
1
Storage controller 1: port 1 to expansion enclosure 1: top EMM, port 1
2
Expansion enclosure 1: top EMM, port 2 to expansion enclosure 2: top EMM, port 1
3
Expansion enclosure 2: top EMM, port 2 to storage controller 2: port 2
1
Storage controller 2: port 1 to expansion enclosure 1: bottom EMM, port 1
2
Expansion enclosure 1: bottom EMM, port 2 to expansion enclosure 2: bottom EMM, port 1
3
Expansion enclosure 2: bottom EMM, port 2 to storage controller 1: port 2
2
Storage controller 1
4
Expansion enclosure 1
Connect the Back-End Cabling
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scv3020

Table of Contents