74
en | Status Codes
Status
Code
15
16**
17
18**
19**
2017.11 | 1.2 |
Description
Attempt was made to move to a pre-
position that is mapped to an
alternate function, so it is no longer
associated with a location.
Motorized zoom function is
programmed to operate at a high
usage level in the Playback Tour.
This high rate of usage could result
in premature wear of the zoom
motor.
Motor operation has been halted
due to an obstruction.
When operating using redundant
power sources, the camera has
detected a loss of power from the
external High PoE power source.
When operating using redundant
power sources, the camera has
detected a loss of power from the
external 24 VAC power source.
User Manual
Recommended action
(to be completed by a qualified Service
Technician)
1. Select/configure a different pre-position
number for the desired location.
2. Re-configure the pre-position assignment
so that this number is no longer associated
with an alternate function. Refer to the
subchapter "Pre-position mapping" in the
User Manual for details on re-mapping pre-
positions.
Re-configure the camera to decrease the
zoom activity to less than 30% during
recording.
1. Remove any obvious materials that are
obstructing operation of the camera pan/tilt
function.
2. If the obstruction is from ice buildup,
review the diagnostic log of the camera
(accessible from the Service menu) for errors
related to the operation of the internal
heaters (and the window defrosters, for MIC
IP fusion 9000i). If the log notes heater or
defroster failure, contact the nearest Bosch
Security Systems Service Center.
3. If operation is obstructed because of
excessive ice buildup, temporarily avoid
operating the pan/tilt functions of the camera
until internal heaters, combined with a rise in
ambient temperature, melt the ice buildup.
1. Verify the operating status of the external
High PoE power source.
2. Verify the integrity of the electrical
connections between the power source and
the camera.
1. Verify the operating status of the external
24 VAC power source.
2. Verify the integrity of the electrical
connections between the power source and
the camera.