Hearth and Home Technologies PVK-80 Installation Instructions Manual page 9

Power vent
Table of Contents

Advertisement

Note: Some fi replace models may
have unique wiring requirements
when used with the PVK-80. In
those cases, PVK-80 instructions
those manuals supersede these
instructions.
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
Figure 17. IPI Wiring Diagram For Fireplace (System 4)
Note: Remove battery pack from
the unit. Battery backup will not
work with the PVK-80.
Note: Some fi replace models may
have unique wiring requirements
when used with the PVK-80. In
those cases, PVK-80 instructions
those manuals supersede these
instructions.
BLACK WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
ON THE HOT SIDE
Figure 18. IPI Wiring Diagram With Pvk-80 Installed (System 4)
9
IGNITION MODULE
3 VAC
WHITE WIRE
CAN BE
PLUGGED
INTO ANY
OF #1-#5
LOCATIONS
ON THE
NEUTRAL SIDE
TRANSFORMER
3 VAC
PLUG IN
IGNITION MODULE
WHITE WIRE CAN BE
PLUGGED INTO ANY OF
#1 - #5 LOCATIONS
TRANSFORMER
ON THE NEUTRAL SIDE
PLUG IN
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
I
S
WHT
ORG
GROUND TO
FIREPLACE
CHASSIS
PIGGYBACK
ON/OFF SWITCH
3 VAC
ORG
GROUND TO
FIREPLACE CHASSIS
3 VAC
PIGGYBACK
SWITCH
VALVE
BLACK
WHITE
INTERMITTENT
PILOT
IGNITOR
VALVE
INTERMITTENT PILOT IGNITOR
TO REMOTE, OR WALL SWITCH
(This connection is 120 VAC, use
appropriate wire and switches).
TERMINAL BLOCK
BLK
BLK
120 V MOTOR
WHT
WHT
BRN
BRN
RED
RED
VACUUM SWITCH

Hide quick links:

Advertisement

Table of Contents
loading