Hearth and Home Technologies PVK-80 Installation Instructions Manual page 10

Power vent
Table of Contents

Advertisement

IPI MODULE
NOT
USED
See Detail B
WALL SWITCH
BACK VIEW
GRN
YEL/WHT
RED
A1
A2
Vacuum Switch
Vacuum Switch is located inside the
PVK Termination Cap
Figure 18. Wiring Diagram For WSK-300HNG
10
BROWN
Detail B
INTERMITTENT
BATTERY
PILOT
PACK
TO
GROUND
CLIP
RED
ORG
BLK
DEXEN IPI VALVE
BRN
NOT
BRN
CONNECTED
ORG
GRN
GRN
GROUND
CONTROL MODULE
JUNCTION BOX (110V)
A3 HI/LOW
See Detail A for J-Box/
Wall Switch Wiring
PVK Termination Cap
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
BROWN wire on cable assembly from
WSK300-HNG to module is cut in half. One
end of brown wire connects to one lead from
vacuum switch, the other brown wire connects
to the other lead wire from the vacuum switch.
MINIMUM 14-3 AWG
WITH GROUND
SWITCH
PVK-80 plugs into
"FAN" outlet on
junction box.
JUNCTION BOX (110V)
RED
Detail A
6000GLX-IPI / Cerona 36 & 42: Power Vent must be
wired to an external 120VAC wall switch (See Detail A).
This switch must be manually turned "ON" and "OFF"
whenever the fireplace is operated with the WSK-300
wall panel.
By turning the Power Vent "ON" the suction created by
the Power Vent closes the vacuum switch which completes
the circuit on the cable assembly (BRN Wire) enabling
the ignition sequence of the WSK300-HNG to operate
the fireplace.
RED
RED
BLACK
BLACK
WHITE
WHITE
GREEN
GREEN
POWER
SUPPLY WIRES
SWITCH BOX