Hearth and Home Technologies PVK-80 Installation Instructions Manual page 7

Power vent
Table of Contents

Advertisement

Figure 13.
2. TO REASSEMBLE THE POWER VENT:
A. Slide the blower assembly into the 10-1/2 in. diam-
eter collar, making sure that the exhaust port on the
blower assembly lines up with the exhaust hole cut
in the 10-1/2 in. diameter collar. See Figure 13.
B. The metal exhaust guide plate will have to be bent
back inside the blower assembly. See Figure 14.
METAL GUIDE PLATE
Figure 14
7
FAN
EXHAUST
PORT
EXHAUST
HOLE
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
INNER RING
COLLAR
Figure 15.
C. Fasten the wire mesh to the 10-1/2 in. collar to
cover the exhaust port hole, using (4) sheetmetal
screws.
D. Slide the inner ring inside the cap assembly, care-
fully positioning the inner ring to its original orien-
tation. See Figure 15. Carefully align the screw
holes on the 10-1/2 in. diameter collar and the inner
ring.
NOTE: This inner ring must be returned to its correct
orientation with the 10-1/2 in. collar for proper blower
operation.
E. Secure the cap assembly to the last vent pipe sec-
tion. Position the power vent assembly with the
exhaust air directed downward to ensure proper
operation.
F. Feed the four (4) wires back through the hole on
the collar and tighten the nut on the right angle
connector. Reconnect the brown and red wire to
the vacuum switch and connect the black and white
wires to the fan motor.
CAUTION: Make sure the cable is NOT in the path of
the hot exhaust air. This can cause the wire insulation
to melt and the Power Vent to malfunction.
G. Reattach the end cap to the cap assembly with four
(4) sheetmetal screws. Position the end cap with
the louvers pointed downward (horizontal termina-
tion).
H. Reconnect the electrical power to the fi replace and
turn the fi replace ON/OFF switch "ON" to ensure
proper operation of the fi replace and power vent.
END CAP

Hide quick links: