Hearth and Home Technologies PVK-80 Installation Instructions Manual page 8

Power vent
Table of Contents

Advertisement

Table 1
PART NUMBER
SL-2DVP
DVP-2SL
Table 2
Table 3
NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run
Figure 16
8
ADAPTOR KITS
Adapts from 4 in./ 6-5/8 in. SL D-series starting collars to 5 in./ 8 in. DVP vent pipe.
Adapts from 5 in./ 8 in. DVP-series starting collars to 4 in./ 6-5/8 SL D-series vent pipe.
DIRECT VENT WITH 4 in./ 6-5/8 in. DIAMETER SL-D PIPE
MAX. ELBOWS
(45° & 90°)
6
DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE
MAX. ELBOWS
(45° & 90°)
10
Note: Some fi replace models may have unique wiring requirements when
used with the PVK-80. In those cases, PVK-80 instructions those manuals
supersede these instructions.
MAXIMUM
VERTICAL
DROP
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
PART DESCRIPTION
MAX. TOTAL VENT
RUN (FT.)
90'
MAX. TOTAL VENT
RUN (FT.)
90'
MAX. VERT.
DROP (FT.)
12'
MAX. VERT.
DROP (FT.)
12'
MAXIMUM
VERTICAL
DROP