Replacement Parts - Hearth and Home Technologies PVK-80 Installation Instructions Manual

Power vent
Table of Contents

Advertisement

Figure 9.

REPLACEMENT PARTS

Replacement parts can be obtained from your dealer.
Repair of the Power Vent should only be done by a
qualifi ed service person.
1. ACCESS TO THE VACUUM SWITCH, TEFLON
TUBING, AND FAN MOTOR:
A. Turn power to off. Remove end cap by removing
the four (4) sheetmetal screws. See Figure 9.
B. Unplug the two wires connected to the vacuum
switch and the two wires connected to the fan motor.
C. Loosen and remove the nut for the right angle con-
nector and carefully pull back the cable to remove
the four (4) wires from the power vent assembly.
D. With the cable loosened from the power vent as-
sembly, remove the sheetmetal screws used to
secure the power vent assembly in place. Firmly
support the assembly to prevent the unit from falling
after the sheetmetal screws have been removed.
See Figure 10.
SUPPORT WHEN
REMOVING
Figure 10.
6
END CAP
REMOVE
SCREWS
Heat & Glo • PVK-80 Power Vent Instructions • 655-900 Rev. O • 12/09
INNER RING
REMOVE SCREWS
Figure 11.
E. Remove the sheetmetal screws from the 10-1/2 in.
diameter pipe and remove the inner ring from inside
the collar. See Figure 11.
IMPORTANT: Take special note of the orientation
of the two part assembly. The inner ring must be re-
turned to its original position for correct Power Vent
operation.
F. Remove the wire mesh that is covering the exhaust
port hole by removing the 4 sheetmetal screws.
G. Bend the metal guide plate at the exhaust port hole
out and through the hole on the 10-1/2 in. diameter
collar. See Figure 12.
METAL GUIDE PLATE
MUST BE IN POSITION
AS SHOWN
Figure 12.
NOTE: On some caps, the metal guide plate is at-
tached to the wire mesh and will slide out with the
mesh.
H. Slide the blower assembly out of the 10-1/2 in.
diameter collar for maintenance or replacement.