BCM450 Hardware & Installation
Desk Mounting the BCM450
Attach the supplied rubber feet
Position the main unit on the required desktop or shelf.
Planning the Installation
Before you install the BCM450 Main Unit or BCM450 Expansion Unit, it is
good practice to follow a preparation check as follows.
Preparation checklist:
Number of lines / handsets / ATA2's etc
Stores check list
Electrical requirements
Ensure you meet the following electrical requirements:
Power must be supplied from a non switchable, third-wire ground AC
electrical outlet.
If you use a power bar, connect the power cord to the power bar and
connect the power bar to the outlet.
Power must be supplied from a nonswitched, unobstructed outlet within
1.5 m (5 ft.) of the BCM450 units.
If you use a power bar, the total length of the power cables from the
power supply to the electrical outlet (including power bar) must not
exceed 2 m
(6.5 ft.).
The supplied power must be a dedicated 110 V to 120 V AC nominal
(or 220 V to 240 V AC nominal), 50 to 60 Hz, 15 A minimum service
with a third-wire safety ground. The third-wire safety ground provides
shock protection and prevents electromagnetic interference.
Do not use an extension cord between the power supply and the power
bar, or between the power bar and the electrical outlet.
Danger: Risk of electric shock
14
NN40011-001 Issue 1.2 BCM450 Rls 6.0