BCM450 Hardware & Installation

Desk Mounting the BCM450

 Attach the supplied rubber feet
 Position the main unit on the required desktop or shelf.

Planning the Installation

Before you install the BCM450 Main Unit or BCM450 Expansion Unit, it is
good practice to follow a preparation check as follows.
Preparation checklist:
 Number of lines / handsets / ATA2's etc
 Stores check list
 Electrical requirements
Ensure you meet the following electrical requirements:
 Power must be supplied from a non switchable, third-wire ground AC
electrical outlet.
 If you use a power bar, connect the power cord to the power bar and
connect the power bar to the outlet.
 Power must be supplied from a nonswitched, unobstructed outlet within
1.5 m (5 ft.) of the BCM450 units.
 If you use a power bar, the total length of the power cables from the
power supply to the electrical outlet (including power bar) must not
exceed 2 m
(6.5 ft.).
 The supplied power must be a dedicated 110 V to 120 V AC nominal
(or 220 V to 240 V AC nominal), 50 to 60 Hz, 15 A minimum service
with a third-wire safety ground. The third-wire safety ground provides
shock protection and prevents electromagnetic interference.
 Do not use an extension cord between the power supply and the power
bar, or between the power bar and the electrical outlet.
Danger: Risk of electric shock