5.
SACD 1000
Signal
Test
point
PCM_Ce_Lf_Fu
F659
r
PCM_LsRs_Fur F504
SPDIF
F644
PM3394B
ch1: freq= 2.79MHz
ch1
1
CH1 1.00 V=
MTB 250ns
SCLK_AV
PM3394B
ch1: freq= 44.3kHz
ch1
1
CH1 1.00 V=
MTB10.0us
LRCLK_AV
Sine wave
Generate the sine wave with the following command
Ref.#
Command Name Remark
117
Sine ON
Then measure the following signals
Signal
Test
point
SCLK_AV
F637
LRCLK_AV
F641
PCMCLK_AV
F640
PCMOUT_AV
F638
PCM_Ce_Lf_Fur
F659
Diagnostic software, trouble shooting and test instructions
type
Level Frequency
No signal
LVTTL N/A
No signal
LVTTL N/A
Data
TTL
N/A
stream
ch1+
CL 06532152_025.eps
051200
ch1+
CL 06532152_026.eps
051200
Play the sine wave at the au-
dio outputs
type
Level Frequency
Clock
LVTTL 3.072MHz
< 0.02%
Clock
LVTTL 48 kHz
< 0.02%
Clock
LVTTL 12.288 MHz
< 0.02%
Data
LVTTL N/A
strea
m
No
LVTTL N/A
signal
Signal
Test
point
PCM_LsRs_Fur
F504
SPDIF
F644
Press "STOP" to switch off the sine wave.
PM3394B
ch1: freq= 3.09MHz
ch1
1
CH1 2.00 V=
MTB 200ns
SCLK_AV 3.072MHz
PM3394B
ch1: freq= 48.1kHz
ch1
1
CH1 2.00 V=
MTB10.0us
LRCLK_AV 48kHz
PM3394B
ch1: freq= 12.2MHz
ch1
1
CH1 1.00 V~
MTB50.0ns
PCM CLK_AV
Pink noise
Generate the pink noise with the following command
type
Level Frequency
No
LVTTL N/A
signal
Data
TTL
N/A
strea
m
ch1+
CL 06532152_027.eps
051200
ch1+
CL 06532152_028.eps
051200
ch1+
CL 06532152_029.eps
051200