Intel S2400SC Technical Product Specification page 32

Hide thumbs Also See for S2400SC:
Table of Contents

Advertisement

Functional Architecture
Error
®
Processor Intel
QuickPath
Interconnect link frequencies not
identical
Processor microcode update missing
Processor microcode update failed
20
Severity
Fatal
The BIOS detects the QPI link frequencies and responds as follows:
Adjusts all QPI interconnect link frequencies to highest common
frequency.
No error is generated – this is not an error condition.
Continues to boot the system successfully.
If the link frequencies for all QPI links cannot be adjusted to be the
same, then this is an error, and the BIOS responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays "0195: Processor Intel
synchronize" message in the Error Manager.
Does not disable the processor.
Takes Fatal Error action (see above) and will not boot until the fault
condition is remedied.
Minor
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Displays "818x: Processor 0x microcode update not found" message
in the Error Manager or on the screen.
The system continues to boot in a degraded state, regardless of the
setting of POST Error Pause in the Setup.
Major
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Displays "816x: Processor 0x unable to apply microcode update"
message in the Error Manager or on the screen.
Takes Major Error action. The system may continue to boot in a
degraded state, depending on the setting of POST Error Pause in
Setup, or may halt with the POST Error Code in the Error Manager
waiting for operator intervention.
Intel order number G36516-002
Intel® Server Board S2400SC TPS
System Action
®
QPI link frequencies unable to
Revision 2.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents