10
10

Finishing

A. Mantel Projections
Figure 10.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance, not the surround.
INLET AIR
EXHAUST
VENT PIPE
VENT PIPE
Figure 10.1 Clearances to Mantels or other Combustibles
above Appliance
B. Installing Trim Surrounds
Combustible materials MUST NEVER overlap onto the
front face.
1. Find the coiled low voltage wires and ON/OFF switch at-
tached to outer right side of the insert (see Figure 10.2).
2. Reconnect the low voltage wires to the ON/OFF
switch.
3. Attach surround assembly by hooking the support
bracket on the locating tabs on top of the gas insert
fi replace (see Figure 10.2.) Once the surround assem-
bly is on the locating tabs, ensure the bottom hooks
are resting on the locating pins at the base. Reposition
the fi replace if necessary. Refer to surround instruc-
tions provided with the decorative surround.
20
12 in. MAX.
MANTEL
12 in. MIN.
MEASUREMENTS FROM
TOP EDGE OF UNIT
Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09
LOCATING TABS
LOCATING SLOTS
Figure 10.2 Trim Surround Installation
FIREBOX