Finishing; Mantel And Wall Projections - Quadra-Fire QFI30-C Owner's Manual

Hide thumbs Also See for QFI30-C:
Table of Contents

Advertisement

11 11

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Clearance to combustible material under the insert is 1/4
inch (6 mm). Clearance from top of fi replace opening for
combustibles extending 12 inches max. is 12 inches.
• Use leveling legs to raise insert minimum 1/4 inch (6 mm)
above combustible material or outer wrap of factory built
fi rebox.
Combustible facings must not extend behind the insert
surround. For non-combustible material specifi cations
refer to section 1.E.
30
Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. H • 7/12
EXISTING NON-COMBUSTIBLE FACING
Figure 11.1 Clearances to Mantels or other Combustibles
above Appliance
12 IN. MAX.
12 IN. MIN.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qfi35-cQfi30

Table of Contents