Battery Charger/Inverter (Option) - JLG 1930ES Service Maintenance Manual

Table of Contents

Advertisement

SECTION 3 - CHASSIS & SCISSOR ARMS

3.12 BATTERY CHARGER/INVERTER (OPTION)

The Battery Charger/Inverter is located on the top of the
chassis at the rear of the machine. Raise and secure scis-
sor arms with arm prop to gain access to the charger.
Figure 3-37. Battery Charger/Inverter Location
5
4
1
2
3
1. AC Output Connector
2. AC Input Connector
3. Remote On/Off Switch Cable
Figure 3-38. Battery Charger/Inverter
3-48
6
4. External DC Fuse Location
5. DC (+) Connection
6. DC (-) Connection
– JLG Lift –
Table 3-5. Battery Charger/Inverter Specs
BATTERY CHARGER/AC
INVERTER
AC INVERTER - SPECS
Output Power (Continuous)
Output Power (Surge)
AC Output Current
AC Output Voltage
Output Frequency
DC Input Voltage
Remote ON/OFF
CHARGER - SPECS
Nominal DC Output Voltage
Maximum DC Output Voltage
Maximum DC Output Current
Required Interlock Current
Input Voltage (AC)
Nominal Input Voltage (AC)
Input Frequency
OPERATION
Charging Indicator
100% Charge Indicator
Fault Indicator
PROTECTION
Output Reverse DC Polarity
Output AC Short Circuit
AC Overload
DC Overload
MECHANICAL
Operating Temperature
Housing
SPECIFICATION
1000 W
3000 W
36 A
115 to 125 VAC
60 Hz
21.2 to 29 VDC
Yes
28 VDC
33 VDC
23 to 27 ADC
1 A
100 to 130 VAC
120 VAC
54 to 66 Hz
Yellow LED
Green LED
Red LED
125 A Replaceable Fuse
Electronic Protection - Automatic
Reset
20 A Internal Slow Blow Charger Fuse
Voltage Limited - Internally Controlled
–40°F to +185°F
(–40°C to +85°C)
Shock and Water Resistant Aluminum
3121166

Hide quick links: