Controls And Indicators; Ground Control Station; Battery Charger Status - JLG 1930ES Operation & Safety Manual

Table of Contents

Advertisement

SECTION 3 - USER RESPONSIBILITIES AND MACHINE CONTROL
Capacities
Raising platform above horizontal with or without any load
in platform, is based on the following criteria:
1. Machine is positioned on a smooth, firm and level
surface.
2. Load is within manufacturer's rated capacity.
3. All machine systems are functioning properly.
Stability
This machine, as originally manufactured by JLG and
operated within its rated capacity on a smooth, firm and
level supporting surface, provides a stable aerial platform
for all platform positions.

3.4 CONTROLS AND INDICATORS

Ground Control Station

DO NOT OPERATE FROM GROUND CONTROL STATION WITH
PERSONNEL IN THE PLATFORM EXCEPT IN AN EMERGENCY.
PERFORM AS MANY PRE-OPERATIONAL CHECKS AND INSPEC-
TIONS FROM THE GROUND CONTROL STATION AS POSSIBLE.
NOTE: When the machine is shut down for overnight park-
ing or battery charging, the emergency stop and
power select switches must be positioned to off to
prevent draining the batteries.
1. Platform/Ground Control Switch
A three position, key-operated power select switch
supplies operating power to the platform or ground
controls, as selected. When positioned to platform,
the switch provides power to the emergency stop
switch at the platform controls. When positioned to
ground, the switch provides power to the ground
control. The ground control emergency stop switch
provides power to the key switch. With the power
select switch in the center off position, power is shut
off to both platform and ground controls.
2. Emergency Stop Switch - A two-position, red, mush-
room-shaped emergency stop switch, when posi-
tioned to ON with the power selector switch
positioned to ground, furnishes operating power to
the ground control station. In addition, the switch
can be used to turn off power to the function con-
trols in the event of an emergency. Power is turned
on by pulling the switch out (on), and is turned off by
pushing the switch in (off).
3-2
3. Platform Lift/Lower Switch - A three position,
momentary contact Lift control switch provides rais-
ing and lowering of the platform when positioned to
up or down.
1
Figure 3-1. Ground Control Station
4. Battery Charger Status - This panel, located to the
right of the ground control box, is designed to give
the operator an accurate read on the status of the
battery charger.
a. Green = Charge complete
b. Yellow = Charging in process
c. Red = Charging abnormal
GREEN
Figure 3-2. Battery Charger Status
– JLG Lift –
2
YELLOW
RED
3121165
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2030es2630es2646es3246es

Table of Contents