Console displays "E2"error code
No speed/RPM reading, Console displays
"E3"error code
Console shuts off (enters sleep mode)
while in use
Check data cable integrity
Check data cable
connections/orientation
Console Electronics
Check data cable integrity
Check data cable
connections/orientation
Check magnet position (requires shroud
removal)
Check RPM Sensor (requires shroud
removal)
Check data cable integrity
Check data cable
connections/orientation
Reset Machine (if equipped with reset
button)
Check magnet position (Technician only-
requires shroud removal)
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Insure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
If tests reveal no other issues, Console
should be replaced.
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Insure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Magnet should be in place on flywheel.
If no magnet is present, replace the
flywheel orthe entire base unit (if unable
to replace flywheel).
RPM sensor should be aligned with
magnet and connected to data cable.
Realignsensor if necessary. Replace if
there is any damage to the sensor orthe
connecting wire.
All wires in the cable should be intact. If
any are cut or crimped, replace cable.
Insure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Unplug unit from electrical outlet for 3
minutes. Reconnect to outlet. After the
Console powers up, press "reset".
Magnet should be in place on flywheel.
If no magnet is present, replace flywheel
or entire base unit.
Check RPM Sensor
Contact Customer Care for further
assistance.
Fan(if equipped) will not turn on or will
not turn off
Unit rocks/does not sit level
Check data cable integrity
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Check data cable
connections/orientation
Insure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
place.
Reset Machine (if equipped with reset
button)
Unplug unit from electrical outlet for
3 minutes. Reconnect to outlet. After
Console powers up, press "reset".
Check leveler adjustment
Levelingfeet may be turned in or out to
level bike.
Check surface under unit
Adjustment may not be able to
compensate for extremely uneven
surfaces. Move bike to level area.