Carrier 070-08/024070 Installation, Start-Up, Operating And Service And Maintenance Instructions page 36

120/c series single-stage deluxe induced-combustion 4-way multipoise furnace
Table of Contents

Advertisement

%
BURNER
J
ORIFICE
Table 9--Speed
Selection
COLOR
SPEED
AS SHIPPED
White
Common
BLW
Black
High
COOL
Yellowt
Med-High
SPARE
Blue
Med-Low
HEAT
Red
Low*
SPARE
* Continuous-blower
speed-as
shipped default
t Not available
on 1/5 HP motors.
A93059
Fig. 53--Orifice
Hole
a. Place theru]ou]eters
in return
and supply ducts
as close to
l_lrnace
as possible.
Be sure
thermometers
do not
see
radiant
heat from
heat exchangers.
Radiant
heat aflccts
teu]perature
rise
readings.
This
practice
is particularly
important
with straight-run
ducts.
b. When
thermon]eter
readings
stabilize,
subtract
return-air
teu]perulure
from
supply-air
temperature
to determine
air
teu]perulure
rise.
NOTI:::
Blower
access door umst be installed
%r proper
teu]pera-
ture rise u]eusureu]eBt.
NOTF::
If the teu]perature
rise is outside
this range,
first check:
1.) Gas input
Ik>r heating
operation.
2.) Derate
lbr altitude
il applicable.
3.) Return and supply ducts lbr excessive
restrictions
causing
static
pressures
greater
than 0.50-in.
we.
4.)Dirty
filter.
ELECTRICAL
SHOCK
HAZARD
Failure
to lollow
this warning
could
result
in personal
inju W
or death.
Disconnect
115-v electrical
power beik>re changing
speed tap.
c. Adjust
air ten]perature
rise
by adjusting
blower
speed.
Increase
blower
speed to reduce teu]perature
rise. Decrease
blower
speed
to increase
temperature
rise.
d. Turn
thermostat
down
below
teen]
teu]perumre
and re-
move
blower
access door.
e. To
change
u]otor
speed
selection
lot
heating,
ren]ove
blower
n]otor
lead fi'on] control
HEAT
ten]dnal
(See Fig.
24.) Select desired
blower
u]otor speed lead l]'on] one of the
other
ten]]inals
and relocate
it to the HEAT
tem]inul
(See
Table
9 Ik_r lead color
identification).
Reconnect
original
lead to SPARE
teru]inal.
f. Repeat
steps a through
e.
g. When correct
input rate and temperature
rise is achieved,
turn gas valve
ON/OFF
switch
to OFF.
h. Reu]ove
munon]eter
or similar
device
l]*om gas valve.
i. Reinstall
muniik_ld pressure
tap plug in gas valve.
FIRE
HAZARD
Failure to %llow this warning
coiuld
result in personal
injury,
death, and/or
property
damage.
Reinstall
mani%ld
pressure
tap plug
in gas valve to prevent
gas leak.
k. Turn gas valve ON/OFF switch to ON.
FURNACE
OVERHEATING
HAZARD
Failure
to this caution
u]ay result
in 17educed l_.trnace lilk:.
Recheck
ten]perature
rise. It nmst
be within
liudts
specified
on the rating
plate.
Reconnnended
operation
is at the mid-
point of rise range
or slightly
above
6. Set theru]ostal
heat anticipator.
a. Mechanical
thern]ostat
Set thermostat
heat anticipator
to
match
the an]p draw
of the electrical
components
in the
R-W circuit.
Accurate
amp draw readings
can be obtained
at the
wires
normally
connected
to thern]ostat
subbase
terlninals,
R and
W. The
therlnostat
anticipator
should
NOT be in the circuit
while
measuring
current.
(1.) Remove
thermostat
fl'om subbase
or from wall.
(2.) Connect
an amp meter as shown
in Fig. 54 across the
R and W subbase
terminals
or R and W wires at wall.
(3.) Record
amp draw across
terminals
when lurnace
is in
heating
and after blower
starts.
(4.) Set
heal
anticipator
on
thermostat
per
thermostat
instructions
and install on subbase
or wall.
b. Electronic
thermostat:
Set cycle rate %r 4 cycles
per hr.
7. Adjust
blower
oK delay
The blower
off delay
has 4 adjustable
settings
l]'om 90 sec to
180 sec. The
blower
off delay jumpers
arc
located
on the
l?lrnace
control
board.
(See Fig. 24.)
To change
the blower
off delay setting,
move the jumper
from
one set of pins on the control
to the pins used liar the selected
blower
off delay.
Factory
off delay setting
is 120 sec.
8. Set airflow
CFM lbr cooling
Select
the
desired
blower
n]otor
speed
lead
%r
cooling
airflow.
See Table
5-Air
Delivery-CFM
(With
Filter).
See
Table 9 %r lead color
identification.
Step
4--Check
Safety
Controls
The flame sensor,
gas valve,
and pressure
switch
were all checked
in the Start-up
procedure
section
as part of noru]al
operation.
1. Check
Main Limit
Switch(es)
This
control
shuts
off combustion
control
system
and ener-
gizes
air-circulating
blower
motor,
if furnace
overheas.
By
using this u]ethod
to check liudt control,
it can be established
that limit is limctioning
properly
and will operate
if there is a
restricted
duct systeu]
or n]otor faihn'c.
If lindt control
does
not function
during
this test, cause
must
be detemdned
and
corrected.
a. Run furnace
liar at least 5 n]inutes.
b. Gradually
block
off return air with a piece of cardboard
or
sheet
u]etal until the liu]it trips.
j. Reinstall blower access door if reu]oved.
36