START-UP, ADJUSTMENT,
AND SAFETY CHECK
Step 1--General
FIRE HAZARD
Failure to l_fllow this warning could result in personal injury,
death and/or property damage.
This lklrnace is equipped with manual reset limit switches in
the gas control area. The switches open and shut off power to
the gas valve if a flame rollout or overheating
condition
occurs in the gas control area. DO NOT bypass the switches.
Correct inadequate combustion
air supply pl'oNem belbrc
resetting the switches.
CUT HAZARD
Faihn'e to lollow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear
appropriate
protective
clothing,
sali:ty glasses
and
gloves when handling parts and servicing furnaces.
1. Maintain
l lS-v
wiring
and ground,
hnproper
polarity
will
result
in rapid flashing
LED
and no furnace
operation.
2. Make thermostat
wire connections
at the 24-v terminal
block
on the furnace
control.
Faihn'e
to make
proper
connections
will result
in improper
operation.
(See Fig. 25.)
3. Gas supply pressure
to the lilrnace
must be greater
than 4.5-in.
wc (0.16
psig ) but not exceed
14-in.
wc (0.5 psig ).
4. Check
all manual-reset
switches
lor continuity.
5. Install
blower
compartment
door.
Door
must
be in place to
operate
furnace.
6. Replace
outer door.
Step
2iStart-Up
Procedures
FIRE AND EXPLOSION
HAZARD
Failure to lollow this warning could cause personal injury,
death and/or property damage.
Never purge a gas line into a combustion chamber. Never use
matches, candles, flame, or other sources of ignition %r the
purpose of checking leakage. Use a soap-and-waer
solution
to check %r leakage.
1. Purge
gas lines after all connections
have been made.
2. Check gas lines liar leaks.

Advertisement