Codes And Standards - Carrier 070-08/024070 Installation, Start-Up, Operating And Service And Maintenance Instructions

120/c series single-stage deluxe induced-combustion 4-way multipoise furnace
Table of Contents

Advertisement

Table 1--Dimensions
0N.)
F
FILTER
D
E
C.L. TOP AND
FLUE
MEDIA
A
SUPPLY-AIR
RETURN-AIR
FURNACE SiZE
CABINET WIDTH
WIDTH
WIDTH
BOTTOM
COLLAR*
SHIP WT (LB)
CABINET
(iN,)
(iN,)
FLUE COLLAR
(iN,)
SiZE
(iN.)
(iN.)
045-08/024045
14-3/18
12-9/18
12-11/18
9-8/18
4
114
18
045-12/036045
14-3/18
12-9/18
12-11/16
9-8/16
4
117
16
070-08/024070
14-3/18
12-9/18
12-11/18
9-8/18
4
121
18
070-12/036070
14-3/18
12-9/18
12-11/16
9-8/16
4
125
16
070-16/048070
17-1/2
15-7/8
18
11-9/18
4
138
18
090-14/042090
17-1/2
15-7/8
18
11-9/18
4
135
16
090-16/048090
21
19-3/8
19-1/2
13-5/18
4
180
20
090-20/080090
21
19-3/8
19-1/2
13-5/18
4
158
20
110-12/036110
17-1/2
15-7/8
18
11-9/18
4
143
16
110-16/048110
21
19-3/8
19-1/2
13-5/18
4
158
20
110-22/086110
21
19-3/8
19-1/2
13-5/18
4
182
20
135-16/048135
21
19-3/8
19-1/2
13-5/18
4
159
20
135-22/086135
24-1/2
22-7/8
23
18-1/18
4
173
24
155-201060155
24-1/2
22-7/8
23
18-1/18
4
180
24
* 5" or 6" vent connector
may be required in some cases.
the "Venting" section of these instructions.
5. Never test liar gas leaks with an open flame. Use a commer-
cially available soap solution made specifically liar the detec-
tion of leaks to check all connections, as specified in the "Gas
Piping" section.
6. Always install lilrnace to operate within the limlace's intended
temperature-rise
range with a duct system which
has an
external static pressure within the allowable range, as speci-
lied in the "Start-Up, Adjustments, and Salety Check" section.
See furnace rating plate.
7. When a lklrnace is installed so that supply ducts carry air
circulated by the luruace to areas outside the space containing
the luruace, the return air shall also be handled by duct(s)
sealed to the Rirnace casing and terminating outside the space
containing the furnace. See "Air Ducts" section.
8. A gas-fired furnace lor installation in a residential garage nmst
be installed as specified in the warning box in the "Location"
section.
9. The fl]ruace may be used lot construction heat provided that
the fllrnace installation and operation complies with the Ill'st
CAUTION in the LOCATION section of these instructions.
10. These Multipoise
Gas-Fired
Furnaces
are CSA (lbrmerly
A.G.A. and C.G.A.) design-certified
ff_r use with natural and
propane gases (see Rirnace rating plate) and liar installation in
alcoves, attics, basements, closets, utility rooms, crawlspaces,
and garages.
The Rirnace is factory-shipped
liar use with
natural gas. A CSA listed gas conversion
kit is required to
convert limmce liar use with propane gas.
11. See Fig. 2 lot required clearances to combustible construction.
12. Maintain a 1-in. clearance
from combustible
materials
to
supply air ductwork lot a distance of 36 inches horizontally
li"om the furnace. See NFPA 90B or local code liar lurther
requirements.
13. These l_.lrnaces SHALL NOT be installed directly on carpet-
ing, tile, or any other combustible
material other than wood
flooring. In downflow
installations,
factory accesso U floor
base MUST be used when installed on combustible materials
and wood flooring. Special base is not required when this
lurnace is installed on manulhcturer's
Coil Assembly Part No.
CD5 or CK5, or when Coil Box Part No. KCAKC is used. See
Fig. 2 l_}l* c learance to combustible construction
inlkmnation.
iNTRODUCTiON
Series 120/C 4 way nmltipoise Category I lau-assisted ll.ll'nace is
CSA design-certified.
A Category I lau-assisted
furnace is an
appliance equipped with an integral mechanical means to either
draw or lorce products of combustion
through the combustion
chamber and/or heat exchanger. The furnace is factou-shipped
lot
use with natural gas. This furnace is not approved lor installation
in mobile homes, recreational vehicles, or outdoors.
This l_lrnace is designed
l_)r minimum
continuous
return-air
temperature of 60°F db or intermittent operadou down to 55°F db
such as when used with a night setback daermostat. Return-air
temperature
must not exceed 85°F db. Failure to l_fllow these
return-air temperature limits may aflcct reliability of heat exchang-
ers, motors, and controls. (See Fig. 3.)
For accessory installation details, reler to the applicable instruction
literature.
NOTE:
Remove all shipping brackets and materials belom oper-
ating the l_rnace.
CODES AND STANDARDS
Follow all national and local codes and standards
in addition to
these instructions.
The installation must comply with regulations
of the serving gas supplier, local building, heating, plumbing, and
other codes. In absence
of local codes, the iustalladou
must
comply with the national codes listed below and all authorities
having jurisdiction.
In the United States and Canada, fl}llow all codes and standards lot
the l_)llowing:
Step l ISafety
[IS: National Fuel Gas Code (NFGC) NFPA 54 2002/ANSI
Z223.1 2002 and the Installation Standards, Warm Air Heating
and Air Conditioning
Systems ANS1/NFPA 90B
CANADA:
CSA B149.1-00
National
Standard
of Canada
Natural Gas and Propane Installation Codes (NSCNGPIC)