Carrier 070-08/024070 Installation, Start-Up, Operating And Service And Maintenance Instructions page 11

120/c series single-stage deluxe induced-combustion 4-way multipoise furnace
Table of Contents

Advertisement

FURNACE
(OR COIL CASING
WHEN USED)
COMBUSTIBLE
FLOORING
SUBBASE
PLENUM
__
FLOOR
__
OPENING
. A96283
Fig. 11iFloor
and Plenum Opening
Dimensions
Fig. 12iFurnace,
Plenum, and Subbase
Installed on
a Combustible
Floor
A96285
FURNACE
CD5 OR CK5
COIL ASSEMBLY
OR KCAKC
COIL BOX
COMBUSTIBLE
FLOORING
SHEET METAL____=._
PLENUM
__
FLOOR
OPENING
A04140
Fig. 13--Furnace,
Plenum, and Coil Assembly or Coil
Box Installed on a Combustible
Floor
A04140
4. If downflow
subbase,
KGASB
is used, install as shown
in Fig.
12. If Coil Assembly
Part No. CD5 or CK5 or Coil Box Part
No. KCAKC
is used,
install
as shown
in Fig.
13.
NOTE:
It is recommended
that
the
perlbrated
supply-air
duct
flanges
be completely
fblded over or removed
li"om furnace
when
installing
the fimlace
on a factory-supplied
cased
coil or coil box.
To remove
the supply-air
duct flange,
use wide duct pliers or hand
seamers
to bend flange back and lbrth until it breaks off. Be careful
of sharp
edges. (See Fig. 14.)
II
Bottom Return Air Inlet
These furnaces are shipped with bottom closure panel installed in
bottom return-air opening. Remove and discard this panel when
bottom return air is used. To remove bottom closure
panel,
perlbrm the lollowiug:
1. Tilt or raise furnace and remove 2 screws holding bottom filler
panel. (See Fig. 9.)
2. Rotate bottom filler panel downward to release holding tabs.
3. Remove bottom closure panel.