General Fault Codes - Siemens SITRANS LR260 Operating Instructions Manual

Radar transmitters
Hide thumbs Also See for SITRANS LR260:
Table of Contents

Advertisement

Priority
Icon
Level
• Data exchanged
• No data exchange
• Write access enabled
• Write access disabled

General Fault Codes

Notes:
• If more than one fault is present, the device status indicator and text for each fault
alternate at 2 second intervals.
• Some faults cause the device to go to Failsafe mode (Fault 52). These are indicated with an
asterisk (*).
Code /
Icon
S: 0
*
The device was unable to get a mea-
surement within the Fail-safe LOE
Timer period. Possible causes: faulty
installation, antenna material
buildup, foaming/other adverse pro-
cess conditions, invalid calibration
range.
S: 2
*
Unable to collect profile because of
a power condition that is outside of
the operating range of the device.
7ML19985KE02
SITRANS LR260 (HART) – INSTRUCTION MANUAL
Meaning (Continued)
General Fault Codes
Meaning
Ensure installation details are cor-
rect. Ensure no antenna material
buildup. Clean if necessary. Adjust
process conditions to minimize foam
or other adverse conditions. Correct
range calibration. If fault persists,
contact your local Siemens repre-
sentative.
Repair required: contact your local
Siemens representative.
Corrective Action
Page 85

Advertisement

Table of Contents