Description And Operation - Chrysler Voyager 2000 GS Instruction

Emission control systems
Table of Contents

Advertisement

25 - 4
EMISSION CONTROL SYSTEMS
DESCRIPTION AND OPERATION (Continued)
(M) Check Engine Lamp (MIL) will illuminate during engine operation if this Diagnostic Trouble Code was
recorded.
(G) Generator Lamp Illuminated
P0132 (M)
1/1 O2 Sensor Shorted To Voltage
P0133 (M)
1/1 O2 Sensor Slow Response
P0134 (M)
1/1 O2 Sensor Stays at Center
P0135 (M)
1/1 O2 Sensor Heater Failure
P0136
1/2 O2 Sensor Heater Relay Circuit
P0137 (M)
1/2 O2 Sensor Shorted To Ground
P0138 (M)
1/2 O2 Sensor Shorted To Voltage
P0139 (M)
1/2 O2 Sensor Slow Response
P0140 (M)
1/2 O2 Sensor Stays at Center
P0141 (M)
1/2 O2 Sensor Heater Failure
P0143
1/3 O2 Sensor Shorted To Ground
P0144
1/3 O2 Sensor Shorted To Voltage
P0145
1/3 O2 Sensor Slow Response
P0146
1/3 O2 Sensor Stays at Center
P0147
1/3 O2 Sensor Heater Failure
P0151 (M)
2/1 O2 Sensor Shorted To Ground
P0152 (M)
2/1 O2 Sensor Shorted To Voltage
P0153 (M)
2/1 O2 Sensor Slow Response
P0154 (M)
2/1 O2 Sensor Stays at Center
P0155 (M)
2/1 O2 Sensor Heater Failure
P0157 (M)
2/2 O2 Sensor Shorted To Ground
P0158 (M)
2/2 O2 Sensor Shorted To Voltage
P0159
2/2 O2 Sensor Slow Response
P0160 (M)
2/2 O2 Sensor Stays at Center
P0161 (M)
2/2 O2 Sensor Heater Failure
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
Neither rich or lean condition is detected from the oxygen
sensor input.
Oxygen sensor heater element malfunction.
An open or shorted condition detected in the ASD or CNG
shutoff relay control ckt.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response not as expected.
Neither rich or lean condition is detected from the oxygen
Oxygen sensor heater element malfunction.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
Neither rich or lean condition is detected from the oxygen
Oxygen sensor heater element malfunction.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage sustained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
Neither rich or lean condition is detected from the oxygen
Oxygen sensor heater element malfunction.
Oxygen sensor input voltage maintained below normal
operating range.
Oxygen sensor input voltage maintained above normal
operating range.
Oxygen sensor response slower than minimum required
switching frequency.
Neither rich or lean condition is detected from the oxygen
Oxygen sensor heater element malfunction.
sensor.
sensor.
sensor.
sensor.
NS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents