Electrical System Maintenance; Electrical System Safety; Servicing The Battery; Removing The Battery - Toro TimeCutter HD X4850 Operator's Manual

Hide thumbs Also See for TimeCutter HD X4850:
Table of Contents

Advertisement

Figure 52
Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before repairing the
g027939
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

Removing the Battery

WARNING
Incorrectly removing the cables from battery
could damage the machine and cables,
causing sparks. Sparks can cause the battery
gasses to explode, resulting in personal
injury.
• Always disconnect the negative (black)
battery cable before disconnecting the
positive (red) cable.
• Always connect the positive (red) battery
g033082
cable before connecting the negative
(black) cable.
1.
Park the machine on a level surface, disengage
the blade-control switch (PTO), and engage the
parking brake.
2.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
3.
Loosen the 2 fasteners on the battery cover
counterclockwise 1/4 turn, and remove the
battery cover
38
(Figure
53).