Parameter Setting Method (Reference) - Mitsubishi FX3U-USB-BD User Manual

Melsec-f fx series programmable controllers
Hide thumbs Also See for FX3U-USB-BD:
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
5.6.2

Parameter setting method (reference)

This subsection explains the parameter setting method using the operation panel.
For details on the operation panel, refer to the respective inverter manual.
Monitor
(4-digit LED)
Show the frequency,
parameter number, etc.
and parameter values.
MODE key
Used to change each setting mode
The operating procedure example below shows a case in which the baud rate is set to 19200 bps.
1
Confirming the RUN indicator and the operation mode indicator
Confirm that the operation is stopped (that the RUN indicator is off).
2
Selecting the parameter setting mode
Press the MODE key, and select the parameter setting mode.
Monitor/frequency
setting mode
3
Setting the parameter Pr. 160 to "0"
(This step is not required if Pr. 160 is already set to "0".)
1. Turn the setting dial until "Pr. 160" is displayed.
2. Press the SET key to read the current set value.
3. Turn the setting dial, and change the set value to "0".
E-52
Parameter setting mode
The previously read parameter
is displayed.
5 Communication Setting in Inverter
5.6 E700, D700 Series (when PU port, FR-E7TR is connected)
Operating status display
Lit or flicker during inverter operation
SET key
Determines each setting