Siemens SIWAREX FTA Device Manual page 166

Weighing electronics for automatic scale
Table of Contents

Advertisement

Messages and Diagnostics
Error
Technology message - description
No.
50
51
52
Weighing stopped, shut-off point is not
plausible
53
Weighing was stopped because set
value < minimum weight
54
Weighing procedure stopped because
weighing range was exceeded
55
Weighing stopped because the fine shut-
off point is not plausible
56
Weighing stopped because of overflow
in totalizing memory 1
57
Weighing stopped because the residual
set value is too low
58
Weighing stopped because weight is
outside measurement range
59
Weighing stopped because there is a
tolerance error
60
Weighing stopped because nothing is
loaded
61
Weighing stopped because net weight
was too high
62
Waiting time for standstill elapsed
63
64
65
66
7-154
Solution
Reserved
Reserved
Dosing stopped since a dosing error led to
shut-off points for coarse and fine signals that
were not plausible.
Dosing stopped because a set value was
determined which was less than the minimum
weight of the weighing range 1 in DR 3 or is
equal to 0 during a totalizing fill.
Dosing stopped because the set value does
not match the current scale status.
The following must apply:
Current gross + set value (DR20 or current
loading set value with) – current trailing +
shut-off correction value < maximum weighing
range
Dosing is stopped because the definition for
the trailing weight or the shut-off correction
value is not plausible. The following must
apply: ( Current trailing - shut-off correction
value) <= set value.
Dosing stopped because totalising the actual
values caused an overflow in distribution
memory 1 in calibratable operation
(Specifications Code OIML in DR 3). Evaluate
the distribution memory and delete it.
Dosing stopped because the quantity to still
be loaded is too small.
The set value to be loaded is less than the
minimum weighing range value in DR 3
Dosing is stopped because the current weight
lies at least 8 weighing steps above the
permitted measurement value range.
Dosing stopped because there is a tolerance
error. This error is only generated if a test has
been defined for tolerance band 1 or 2 in
DR 23.
Loading stopped because nothing has been
emptied for the last fill or less than the
minimum weight of weighing range 1 (DR3)
was emptied with specification code =
OIML (DR3).
Dosing stopped because the net weight
already lies above the coarse weight.
Waiting time for standstill 2 elapsed, ongoing
dosing is not interrupted.
Reserved
Reserved
Reserved
Reserved
SIWAREX FTA