Weighing Functions
Bit No.
17
RS232-Print not possible
18
MMC inserted
19
MMC ready
20
MMC-trace ready
21
MMC-log ready
22
Trace active
23
Min. through-put 1 overshot
24
Min. through-put 2 overshot
25
Empty message
26
Calibration data protection
27
Starting up
28
MMC data ready S7
29
Digital LC active
30
Stand-alone operation
31
Operating error
Table 5-19
DR 30 - NAWI status bits

5.19.2 DR 30 - AWI status flags

Bit No.
0
Weighing steps
1
2
3
4
5
6
7
8
Post dosing active
9
Course signal
10
fine signal
11
Timer pre-dosing
Empty signal
12
13
Weighing stopped
14
Weighing stopped because
of check stop
15
Check stop follows
16
Last weighing procedure
aborted
17
Weighing blocked
18
TO2
19
TO1
20
Good
21
TU1
22
TU2
23
TOL bad
24
Standstill 2
25
Standstill 3
26
Check to follow
5-112
Name
The log cannot be printed.
The MMC is in position
The MMC is formatted and ready for recording
The MMC is ready for the trace function
The MMC is ready for logging
The trace function is activated
Through-put monitor 1 activated
Through-put monitor 2 activated
Scale in empty range
The switch for protecting the calibration data is switched on
Set during the warming up phase (duration 1 min, no
commands given, in Ascii weight DR 34 the FW-Version is
shown)
Preparing the MMC data with the default in DR 46 ended for
S7 interface DR 47
0 = Digital load cell recording not active
1 = Digi load cell recording is running
0 = SIMATIC operation activated
1 = Stand-alone operation activated
At least one operating error (fault) exists
Name
Current weighing control step
0 to 7
Post dosing is active
The coarse signal is switched on
The fine signal is switched on
The timer for pre-dosing is active
The empty signal is switched on
The weighing cycle has been stopped
The weighing cycle has been stopped because of the check
stop command
The weighing cycle will be stopped by a check stop
(is set with the check stop command and reset if the check
stop is achieved)
Last weighing procedure aborted with "Residual weighing"
or "Reset weighing control".
Set if the step-on to the next step in the weighing cycle is
blocked because of a missing step enable.
Net weight above the TO2 limit
Net weight above TO1
Net weight in tolerance TU1 to TO1
Net weight under TU1 but over TU2
Net weight under TU2
Net weight under TU2 or over TO2
Stand-still 2 exists
Stand-still 3 exists
A control weighing is run at the end of the cycle
Range of Values / Explanation
Range of Values / Explanation
Reference
Reference
SIWAREX FTA