Weighing Functions
5.16.21 DR 23 - Stop on TO1
This parameter defines whether the automatic processing should stop if the current
net weight increases to more than the set value plus TO1.
0: Weighing procedures not stopped for tolerance error
1: Weighing stopped because of tolerance error (weight above TO1)
5.16.22 DR 23 - Stop on TO2
This parameter defines whether the automatic processing should stop if the current
net weight increases to more than the set value plus TO2.
0: Weighing procedures not stopped for tolerance error
1: Weighing stopped because of tolerance error (weight above TO2)

5.16.23 DR 23 - Stop with TU1

This parameter can be used to define whether the automatic progress should
continue if the current net weight has become less than the set value minus TU1.
0: Weighing procedures are not stopped because of tolerance errors
1: Weighing procedure is stopped because of tolerance error (weight under TU1)
5.16.24 DR 23 - Stop with TU2
This parameter can be used to define whether the automatic progress should be
stopped if the current net weight has become less than the set value minus TU2.
0: Weighing procedures are not stopped because of tolerance errors
1: Weighing procedure is stopped because of tolerance error (weight under TU2)
5.16.25 DR 23 – Continue upon stop because of TOL error
This parameter can be used to define whether the weighing cycle is permitted to
continue or not with the "Continue" instruction, even though a tolerance error exists
after a stop because of a tolerance error.
0: Cycle cannot be continued because of a tolerance error
1: Cycle can be continued with the instruction "Continue (103)" when a
tolerance error occurs
5.16.26 DR 23 - Control pauses
To increase the material throughput, it may be sensible in certain filling systems to
avoid checking every weighing procedure (applies only in AWI Singe/Continous
operating mode).
This parameter defines how often that the tolerance check should be done.
0: Tolerance deviation checked every weighing procedure.
1: A weighing procedure is not checked for tolerance deviations
5-104