4.2.5.8 Removing the PE Paper Detector Assembly
1.
Remove the housing. (Refer to Section 4.2.1.)
2.
Move the carriage out of the home position.
3.
Release two fixed hooks securing the PE detector assembly from the back of the frame
and remove the PE detector assembly, sliding it upward. Remove the PE board
assembly and PE lever, if necessary.
During assembly, make sure that the tip (sensor part) of the detector
lever is in the hole of paper guide assembly.
Disassembly & Assembly
After releasing two hooks, remove the PF
paper detector assembly, sliding it
This side should be
installed on the
frame.
PE Board
Assembly
Figure 4-19. Removing the PE Detector Assembly
Disassembly Procedures
upward.
PE Holder
Torsion Spring 0.22
Revision A
(From back side of the
frame)
PE Lever
115