Preparing For Convergence Adjustment - Barco ZEUS Installation And Safety Manual

Table of Contents

Advertisement

12. Convergence

12.2 Preparing for convergence adjustment

Necessary tools
7mm flat screwdriver.
3mm Allen wrench.
How to set up the projector for convergence adjustment?
1. Remove the top cover from of the projector. See procedures page 144.
2. Remove the left side cover from of the projector. See procedures page 145.
3. Remove the top cover plate of the Light Processor compartment. See page 146.
4. Remove the left cover plate of the Light Processor compartment. See page 148.
5. Place the fan on top of the Light Processor in the upper position as illustrated. Do this by engaging the two lower slots (reference
2 image 12-3) into the upper mounting pins as illustrated. The two upper slots (reference 3 image 12-3) remain free.
Image 12-3
6. Switch on the projector, ignite the lamp and open the dowser.
7. Select the convergence test pattern, which is illustrated below (image 12-4). Use the communicator to activate the convergence
test pattern.
Note: The convergence test pattern can NOT be activated via the PATTERN button on the Local Keypad.
2
5
Image 12-4
96
3
6
1
4
3
2
R5905961 ZEUS 09/03/2015