Bridge Id - Cisco Nexus 9000 Series Configuration Manual

Nx-os layer 2 switching configuration
Hide thumbs Also See for Nexus 9000 Series:
Table of Contents

Advertisement

Configuring Rapid PVST+ Using Cisco NX-OS
• The system elects a unique root switch for the spanning tree network topology.
• The system elects a designated switch for each LAN segment.
• The system eliminates any loops in the switched network by placing redundant switch ports in a backup
state; all paths that are not needed to reach the root device from anywhere in the switched network are
placed in an STP-blocked state.
The topology on an active switched network is determined by the following:
• The unique device identifier Media Access Control (MAC) address of the device that is associated with
each device
• The path cost to the root that is associated with each switch port
• The port identifier that is associated with each switch port
In a switched network, the root switch is the logical center of the spanning tree topology. STP uses BPDUs
to elect the root switch and root port for the switched network.
The mac-address bpdu source version 2 command enables STP to use the new Cisco MAC address
Note
(00:26:0b:xx:xx:xx) as the source address of BPDUs generated on vPC ports.
To apply this command, you must have identical configurations for both vPC peer switches or peers.
Cisco strongly recommends that you disable ether channel guard on the edge devices before issuing this
command to minimize traffic disruption from STP inconsistencies. Re-enable the ether channel guard
after updating on both peers.

Bridge ID

Each VLAN on each network device has a unique 64-bit bridge ID that consists of a bridge priority value, an
extended system ID (IEEE 802.1t), and an STP MAC address allocation.
Bridge Priority Value
The bridge priority is a 4-bit value when the extended system ID is enabled.
You can only specify a device bridge ID (used by the spanning tree algorithm to determine the identity of the
root bridge; the lowest number is preferred) as a multiple of 4096.
In this device, the extended system ID is always enabled; you cannot disable the extended system ID.
Note
Extended System ID
The device always uses the 12-bit extended system ID.
Cisco Nexus 9000 Series NX-OS Layer 2 Switching Configuration Guide, Release 7.x
STP
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents