3 Electrical Installation

3
Electrical Installation
The figure below shows the main and control circuit wiring.
Wiring sequence should shut off
power to the drive when a fault
output is triggered.
ELCB (MCCB)
R
Three-phase
power supply
S
200 to 240 V
T
50 / 60 Hz
MC
MB
2MCCB
THRX
OFF
ON
MC
SA
MC
Braking resistor unit
Thermal relay trip contact
THRX
1
2
SA
TRX
SA
MC MA
TRX
Multi-function
Fault relay
contact
(default setting)
Multi-function
analog inputs
<1> Remove the jumper when installing a DC reactor. Models CIMR-L20085 through 20415 and 40045 through 40216 come with a
built-in DC reactor.
<2> The drive provides a stop function in compliance with Stop Category 0 (EN 60204-1) and "Safe Torque Off" (IEC/EN 61800-5-2). It has been
designed to meet the requirements of the ISO/EN 13849-1, Category 3 PLd, and IEC/EN 61508, SIL2. Using this function the number of motor
contactors can be reduced to one. Refer to
<3> Never short terminals SP and SN, as doing so will damage the drive.
<4> Disconnect the wire jumper between H1-HC and H2-HC when utilizing the Safe Disable inputs.
Note: 1.
The drive should be implemented in the system in a way so that a drive fault causes the safety chain to open. Always use terminal
MA-MB-MC for this purpose.
2.
Even though no fault is present, conditions where the drive may not start can occur, e.g. when the Digital Operator is left in the
Programming Mode. Use the "Drive Ready" output (default set to terminals M5-M6) to interlock operation in such situations.
EN 12
Terminals -, +1, +2, B1, B2 are
for connecting options. Never
connect power supply lines to
these terminals
2MCCB
r1
s1
t1
Fuse
MC
R/L1
EMC
S/L2
Filter
T/L3
If running from a 400 V power
supply, a step-down transformer
is needed to reduce the voltage
to 200 V.
Up command / Stop
S 1
Down command / Stop
S 2
Nominal Speed
S 3
Inspection Operation
S 4
S 5
Intermediate Speed 1
Leveling Speed
S 6
digtial inputs
Not Used
S 7
Not Used
S 8
SN
SC
Sink / Source mode
selection wire link
<3>
SP
(default: Sink)
+
V
2 k Ω
A 1
A 2
AC
V
+
+
R
R
+
+
MEMOBUS/Modbus
S
comm. RS485/422
max. 115.2 kBps
S
IG
H 1
H 2
Safe Disable inputs
<4>
HC
Safe Disable Input Function on page 48
<1>
DC reactor
Thermal relay
(option)
(option)
U
U
X
X
Jumper
+
+
+
+
2
1
B 1
B 2
Braking resistor
(option)
Main Circuit
Drive
Control Circuit
Option card connectors
CN5-C
CN5-B
CN5-A
Terminal board
jumper and switch
DIP Switch S2
Off
On
Term. Res. On/Off
Jumper S3
H1, H2
Sink/Source Sel.
+ 24
V
Shield ground terminal
Power supply +10.5 Vdc, max. 20 mA
Analog Input 1 (Speed Bias)
-10 to +10 Vdc (20 kΩ)
Analog Input 2 (Not used)
-10 to +10 Vdc (20 kΩ)
0 V
Power supply, -10.5 Vdc, max. 20 mA
Termination resistor
(120 Ω, 1/2 W)
DIP
Switch S2
for details.
YASKAWA ELECTRIC TOEP C710616 33G AC Drive L1000A - Quick Start Guide
<2>
U/T 1
V/T 2
W/T
3
Shielded
Cable
Ground
YEG
MA
Fault relay output
250 Vac, max. 1 A
MB
30 Vdc, max 1 A
MC
(min. 5 Vdc, 10 mA)
M 1
Multi-function relay output (Brake Control)
250 Vac, max. 1 A
M 2
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
M 3
Multi-function relay output (Output Contactor Control)
250 Vac, max. 1 A
M 4
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
M 5
Multi-function relay output (Drive Ready)
250 Vac, max. 1 A
M 6
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
P1
Photo Coupler 1
C1
(During Frequency Output)
P2
Photo Coupler 2
C2
(not used)
FM
Multi-function analog output 1
+
(Output Speed)
FM
-10 to +10 Vdc (2mA)
AM
Multi-function analog output 2
+
AC
(Output Current)
AM
-10 to +10 Vdc (2mA)
0 V
E (G)
+
+
DM
EDM (Safety Electronic Device Monitor)
DM
U
Motor
V
M
W
Digital output
5 to 48 Vdc
2 to 50 mA
(default setting)
shielded line
twisted-pair shielded line
control circuit terminal
main circuit terminal