3.2.3.3 Mandatory Commands

The data packet from the host to the reader is known as the request and the reply from the
reader to the host as the response. The host is always the primary station and initiates all
communication sequences. These consist of request/response pairs where the host waits for a
response before continuing. All ISO/IEC 15693-3 command request packets are contained
within the standard reader command request packet format. In all cases, reader command 60
is used to pass through ISO 15693 Part 3 commands to the reader.
Inventory: Command Code (01
ISO Inventory Request Command Packet
Header
'01
'
hex
SOF
Not
Used
ISO Inventory Response Packet
The inventory response packet format, while complying with ISO 15693, is unique to the
reader and is described within the following illustrations.
responses contain ISO 15693 data as detailed within ISO/IEC 15693-3.
Header
Packet
Length
'01
'
2 bytes
hex
SOF
Valid Data
Flags
Not
2 bytes
Used
LSB/MSB
)
hex
Packet
Node
Cmd
Length
Address
Flag
2 bytes
2 bytes
1
byte
ISO Inventory Request Format
Flags
Inventory
Opt.
Command
1
'O1
'
hex
byte
byte
Node
Response
Address
Flags
2 bytes
1 byte
ISO Inventory Response Format
Collision
Flags
2 bytes
Data returned from 1
LSB/MSB
S6350 Midrange Reader Module - Reference Guide
Cmd
ISO Command Data
Config. Byte
'60
'
Byte 0
hex
Mask
Mask
AFI
Length
Value
1
1 byte
0 - 7
bytes
Command
ISO Response Data
'60
'
hex
80-bit response to
Inventory Command
st
valid time slot
30
Check
-sum
Data
bytes
2
1 - n
bytes
CRC16
EOF
Not
Not
Used
Used
All other ISO 15693 packet
Check
sum
Data
bytes
2 bytes
0 - m
Etc...
CRC16
EOF
Etc...
Not
Not
Used
Used
hex