10.1.9

Technical data

Table 10- 15 Technical data
6SL3055-0AA00-3BAx
Current requirement (X524 at 24 V DC)
without DRIVE-CLiQ supply
Current requirement (X514 at 24 V DC)
without digital outputs and sensor power supply
Sensor power supply with and without forced dormant error
detection (L1+, L2+, L3+)
Voltage
Max. load current per output
- cable length for the 24 V power supply:
- For longer cable lengths, the "Weidmüller Type No. PU DS
24 16A" surge protector must be used.
Fail-safe digital inputs (F-DI)
(with electrical isolation)
Fail-safe digital outputs (F-DO)
(with electrical isolation)
Standard digital inputs
(with electrical isolation)
Fail-safe digital inputs (F-DI) and standard digital inputs
Voltage
Low-level (an open digital input is interpreted as "low")
High level
Current consumption (at 24 V DC)
Input delay
1)
- for "0" to "1"
- for "1" to "0"
Fail-safe digital outputs (F-DO), continuous short-circuit proof
Voltage
Max. load current per digital output
Output delay
1)
- for "0" to "1"
- for "1" to "0"
Power loss
PE/ground connection
Weight
Pure hardware delay
1)
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
Unit
mA
mA
V
A
m
V
V
V
mA
μs
μs
V
A
μs
μs
W
kg
Additional system components
10.1 Terminal Module TM54F
Value
160
38
24
0.5
< 30
10
4
4
0 to 30
-3 to +5
15 to 30
>2
approx. 30 (100 Hz)
approx. 60 (100 Hz)
24
0.5
300
350
4.5 at 24 V
On enclosure with
M4 screw
approx. 0.9
191