Pointer And Scale; Adjusting Pointer - Delta 36-075 Instruction Manual

10' compound power miter saw
Hide thumbs Also See for 36-075:
Table of Contents

Advertisement

1 6
Fig.
1 5
Fig.
ROTATING TABLE FOR MITER CUTTING
Your miter saw will cut any angle from a straight 90 degree cullo 47 degrees right and
left. Simply loosen lock handle (A) Fig. 15, one ortwo turns, depress index lever (B)
and move the control arm to the desired angle. THEN TIGHTEN LOCK HANDLE (A).
The miter saw is equipped with positive stops at the 0,22-112, and 45 degree right and
left positions. Simply loosen lock handle (A) Fig. 15, and move the control arm untilthe
bottom of the index lever (B) engages into one of the positive stops, four of which are
shown at (C). THEN TIGHTEN LOCK HANDLE (A). To disengage the positive stop,
depress index lever (B).
In addition, a triangle indicator (D) Fig. 16, is provided on the miter scale at the 31-5/8
right and left miter positions for cutting crown moulding. Refer to the "CUTTING
CROWN MOULDING" section of this manual,
IMPORTANT ALWAYS TIGHTEN LOCK HANDLE (A) Ftc. 16, BEFORE CUTT|NG.
POINTER AND SCALE
A pointer (E) Fig. 17, is supplied which indicates the
actual angle of cut. Each line on the scale (F) represents
112 degree.In effect, when the pointer is moved from one
line to the next on the scale, the angle of cut is changed
by 112 degree.
ADJUSTING POINTER
lf it becomes necessary to adjust the pointer (E) Fig. 17,
simply loosen screw (G), adjust the pointer accordingly
and tighten screw (G).
Fig.1 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents