Problem
The unit is not
working
The unit starts and
stops frequently
Poor heating
performance
Possible Causes
Power failure
The power is turned off
The fuse is burned out
Remote control batteries
are dead
The Unit's 3-minute
protection has been
activated
Timer is activated
There's too much or too
little refrigerant in the
system
Incompressible gas or
moisture has entered the
system.
The compressor is broken Replace the compressor
The voltage is too high or
too low
The outdoor temperature
is exetremtly low
Cold air is entering through
doors and windows
Low refrigerant due to leak
or long-term use
Solution
Wait for the power to be
restored
Turn on the power
Replace the fuse
Replace batteries
Wait three minutes after
restarting the unit
Turn timer off
Check for leaks and
recharge the system with
refrigerant.
Evacuate and recharge
the system with
refrigerant
Install a manostat to
regulate the voltage
Use auxiliary heating
device
Make sure that all doors
and windows are closed
during use
Check for leaks, re-seal if
necessary and top off
refrigerant