IBM Storwize V7000 Maintenance Manual page 141

Table of Contents

Advertisement

Table 26. Error event IDs and error codes (continued)
Event
Notification
ID
type
Condition
045021
E
A canister was removed from the system.
045022
E
A canister has been in a degraded state for too long and
cannot be recovered.
045023
E
A canister is encountering communication problems.
045024
E
The canister VPD is not valid.
045025
E
The canister has experienced too many resets.
045026
E
The drive slot is causing the network to be unstable.
045027
E
The drive slot is not running at 6 Gbps
045028
E
The drive slot is dropping frames.
045029
E
The drive is visible through only one SAS port.
045031
E
The drive power control is not functional.
045033
E
The drive slot contains a device that is not responding to
queries.
045034
E
The managed enclosure is not visible from any node
canisters.
045035
E
The electronics in the enclosure has failed.
045036
E
The electronics in the enclosure has experienced a critical
failure.
045037
E
The SAS network has too many errors.
045038
E
The SAS network has too many errors.
045040
W
The firmware update for the enclosure component has
failed.
045041
W
More than one initiator port was detected on the same
strand.
045042
W
The order of the enclosures is different on each strand.
045044
W
Multiple canisters are connected to a single canister port. 1005
045045
W
Canister 1 is connected to canister 2.
045046
W
An enclosure is connected to more than one I/O group.
045047
W
A managed enclosure is connected to the wrong I/O
group.
045048
W
An enclosure is connected to more than one chain.
045049
W
Too many canisters are connected to a strand.
045050
W
The canister is connected to the wrong port.
045051
E
A SAS cable is excluded because of single port active
drives.
045052
W
More than one canister was detected at the same hop
count.
045053
E
The node location is not able to be detected.
045054
E
An enclosure display cannot be updated.
045055
E
There is an enclosure battery fault.
045056
E
An enclosure battery is missing.
045057
E
An enclosure battery is nearing end of life.
Error
code
1036
1034
1038
1032
1032
1686
1686
1686
1686
1008
1685
1042
1694
1008
1048
1048
3015
1005
1005
1005
1005
1005
1005
1005
1005
1260
1005
1031
1694
1118
1112
1114