Operation During A Power Outage - Intellifire™ Touch - Heat & Glo COSMO42-IFT Owner's Manual

Hide thumbs Also See for COSMO42-IFT:
Table of Contents

Advertisement

I. Operation During A Power Outage - Intellifire™ Touch
The Intellifire™ Touch intermittent pilot ignition system
comes with a battery backup system that enables the
system to operate in a power outage. The system offers
seamless transition from household AC power to battery
backup. A factory-installed battery pack is located in the
control cavity of the appliance. See Figure 3.6. Battery
longevity and performance will be affected by long term
exposure to the service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Note: The battery backup system is disabled if either
a Power Vent option or the Smart-Wall™ option
has been installed for use with this appliance.
To Operate Fireplace Using Battery Power (DC):
1. The battery pack is located in the control cavity of the
appliance. To access the control cavity of the appliance
Remove the decorative front and glass assembly. See
Section 4 for instructions on glass assembly removal.
See Figure 3.6 for location of battery pack.
2. Locate the battery pack and remove it from the control
cavity. It is held in place by hook and loop fastener.
Insert four AA cell batteries. Battery polarity must be
correct or module damage will occur. See Figure 3.6.
A complete wiring diagram is included in the Electrical
section of the appliance Installation Manual.
3. Turn the appliance on according to the instructions
below for the appropriate type of control:
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
• Toggle the switch as you would under normal
circumstances.
Wireless Remote:
• Remote receiver is integrated into the ignition module.
• Use the remote to turn the appliance on.
• To preserve battery life, do not use the HI/LO flame or
THERMOSTAT options.
Ignition Module:
• Locate the ignition module in the control cavity.
• Slide the ON/REMOTE/OFF switch to the ON position.
NOTICE: Some functionality will be lost when using battery
backup including fan, lights, or any other auxiliary functions
that require household 110-120 VAC power.
14
Heat & Glo • COSMO42-IFT, COSMO32-IFT Owner's Manual • 2491-981 Rev. B • 11/17
To Return to Operation Using Electrical (AC) Power
Standard Wall Switch or Factory-Installed ON/OFF
Switch:
Toggle the switch to OFF and remove the batteries
from the battery tray. Replace door or decorative front
on appliance.
Wireless Remote:
Slide the ON/REMOTE/OFF switch to the REMOTE
position. Remove the batteries from the battery tray.
Replace door or decorative front on appliance.
Ignition Module:
Slide the ON/REMOTE/OFF switch to the REMOTE
position.
Remove the batteries from the battery tray. Replace
door or decorative front on appliance.
BATTERY PACK
LOCATED IN
CONTROL CAVITY
Figure 3.6 Battery Pack Location/Control Cavity