Note: For #-marked boxes, values that are set at the Analog Calibration dialog box are
displayed.
Equipment Category*:
Board Name*:
Note*:
* Marked Items: For easy identification of input source, enter Equipment Category,
Brand, Type No., Data and Name.

2.5 Digital Signal

Digital signal is connected via Junction Box IF-8530 (optional for VR-3000S). The
receivable signal is 10-32 V for voltage signal, or contact signal. For voltage signal,
connect to A and B input terminals on the Junction Box. For contact signal, connect to B
and G input terminals on the Junction Box. Also, make a short-circuit between the 24 and
A input terminals with a jumper wire.
To set up the Digital tab:
1. Click the Digital tab.
2. Select a channel from the Information Area.
3. Set up the digital signal from the Setting Area. Refer to the following individual item
explanation.
In the factory settings, there is no preset data when the Select Equipment button is
pressed. In the case that the setup was completed on another ship and saved using
Reflect Equipment, import the data by clicking Select Equipment and choosing the
saved data.
4. When setting Digital Signal to each 64 channel group, perform the following
directions:
1. Click the Calibration button in the setting area.
Set equipment category.
Enter board names where channels are present.
Enter note.