Furuno VR3000 Instruction Manual page 13

Vdr maintenance viewer
Hide thumbs Also See for VR3000:
Table of Contents

Advertisement

Place the cursor above either I, or N, and left click to alternate. With this, I is set to
record while N is set to not record. G cannot be changed.
4. After completing setup, click the OK button.
5. To record settings to the database, click Reflect Equipment in the Setting Area.
How to Enter Information Manually
This VDR system receives in VESA (Video Electronics Standards Association) signal.
Image signal: 0.5-1Vpp (When using composite signal, the minimum synchronization
signal is 50 mV).
Horizontal Synchronization Signal: Max. ±91146 kHz.
Vertical Synchronization Signal: Max. 35 Hz.
Acceptable Image Resolution: 640x480 – 1280x1024.
Channel number conforms to the number displayed by the DCU.
To set the Radar tab, do the following:
1. Click the Radar tab.
2. Choose the channel with the entered Radar Image from the Information Area.
3. Check the Active box in the Setting Area and enter the Horizontal and Vertical
resolution of the incoming image in the Horizontal resolution and Vertical resolution
columns.
4. Click the Set button.
5. Click the Image Capture... button. The Image Capture dialogue box appears.
6. Click the Test button in the Image Capture window. Radar image appears a few
seconds later.
7. If the image is normal, close the Image Capture window.
8. Input each item in the Setting Area.