16 April '88

6. Stopper Plate Position Adjustment

Reinstall the stopper plate as follows:
1. Remove the spring [A] of the friction roller release solenoid [B] and keep
the solenoid plunger inside the coil.
2. Loosen the two screws of the stopper plate [C].
3. Position the plate so that the groove of the cam [D] aligns with the ".4"
calibration mark.
NOTE: -
This means that the overlap of the feed and friction rollers is
adjusted to
feed roller.
- If the cam cannot align with the ".4" mark, reposition the roller
release solenoid by loosening the solenoid mounting screws.
4. Replace the spring of the solenoid.
NOTE: -
If multiple feeding occurs, increase the overlap by repositioning
the stopper plate.
- If the original becomes smeared, decrease the overlap.
mm when the friction roller is released from the
0.4