Feac Alarm Messages And Loop Codes - JDS Uniphase CT-650 Reference Manual

Wideband test unit command-line reference guide
Table of Contents

Advertisement

Appendix B Command Parameter Definitions

FEAC alarm messages and loop codes

Table 9
Example digroup number formats (Continued)
DCS
Lucent DACS IV
TELLABS 5500
FEAC alarm messages and loop codes
188
Circuit
Format
DS1
xx-yy-zz, where: xx=1–32 (rack), yy =1–31 (shelf), zz=1–
28
STS-1/
x-y-z, where: x= 1–64 (Unit), y = 1–15 (Slot), z=1–28
VT1.5
(Port); or w-x-y-z, where: w= 1–64 (Unit), x = 1–15 (Slot),
y = 1–7 (VT group), z = 1–4 (VT number)
DS1
xxx-yy, where: xxx = 1–1024 (SDF), yy = 1–28 (channel
within the SDF)
STS-1/
VT1-xxxx-y-z, where: xxxx = 1–1024 (SDF), y = 1–7 (VT
VT1.5
group), z = 1–4 (VT number)
For DS3 testing with C-bit framing, you can specify the alarm message
issued by the FEAC_Alarm command (see
Table 10 FEAC alarm messages
Message
Com_Eq_Fl_NSA
DS1_M_LOS/HBER
DS1_NSA_Eq_Fl
DS1_SA_Eq_Fl
DS1_S_LOS/HBER
DS3_AIS_Rcvd
DS3_Idle_Rcvd
DS3_LOS/HBER
DS3_NSA_Eq_Fl
CT-650 Command-Line Reference Guide
page
43).
Description
Common Equipment Failure, Non-Ser-
vice Affecting (Type 2 equipment failure)
DS1 Multiple Loss-of-Signal/High Bit
Error Ratio
DS1 Non-Service Affecting Equipment
Failure (Type 2 equipment failure)
DS1 Service Affecting Equipment Failure
(Type 1 equipment failure)
DS1 Single Loss-of-Signal/High Bit Error
Ratio
DS3 Alarm Indication Signal Received
DS3 Idle Signal Received
DS3 Loss-of-Signal/High Bit Error Ratio
DS3 Non-Service Affecting Equipment
Failure (Type 2 equipment failure)
Release 9.4

Hide quick links:

Advertisement

Table of Contents
loading