Finishing Material - Napoleon HIGH COUNTRY NZ5000 Installation Manual

Hide thumbs Also See for HIGH COUNTRY NZ5000:
Table of Contents

Advertisement

Available languages

Available languages

framing
EN
5.1

finishing material

WARNING
!
Screws used to fasten finishing materials to the face of the appliance above the guillotine screen and door
must not penetrate more than 1/2" (13mm) into the sheet metal front panels. Refer to the "dimensions"
section for specific requirements.
Do not pack air spaces with insulation or other materials.
Use only a non-combustible material to finish the face of the appliance. A non-combustible material such
as cement board is required for this purpose.
Ventilation openings are mandatory for enclosures.
Above 73 5/8" (187cm) combustible finishing materials may be used on the front face (measured appliance
from base of unit).
Do not insulate around the appliance.
framing and facing must
have a minimum height
of 73 5/8" (187cm)
from the base of the
Non-combustible
board from the side
of the appliance to
combustibles; as
measured from the
side of the faceplate.
note:
Before you completely close up the enclosure, ensure the air control, flue damper and the door / screen
assemblies perform as intended.
22
W415-1720 / C / 10.27.17
Combustible
board
Non-combustible
board
Non-combustible
appliance.
Faceplate
8 1/2"
(216mm)
36 5/8"
(93cm)
Use metal studs wherever
non-combustible facing is required.
Steel
Min. enclosure
ceiling height
84" (213.4cm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents