The Embedded Data dialog box is shown in Figure 2-15. For this message, select a data
format of "None" since there is no data to be displayed. To force acknowledgement of the
message, select the "User must acknowledge message" check box.
Note
If you have more than one embedded data value in a message, you only need to select
the acknowledgement check box for the first embedded data value in the message. The
TD 200 ignores the acknowledge bit in all subsequent data values of the message.
For this example, make the selections shown in Figure 2-15 and click on the "OK" button to
return to the message configuration dialog box.
Embedded Data
Data Format:
User must acknowledge message
Is the user allowed to edit this data?
Delete
Figure 2-15 Embedded Data: Requiring Acknowledgement of Message
SIMATIC TD 200 Operator Interface
C79000-G7076-C205-04
Display Format:
None
Signed
Word
Unsigned
Double Word
Configuring the TD 200
Digits to the right of the
decimal
0
OK
Cancel
2-15