Platform Out of Level (Platform
Level > 15 Degrees Fault)
If ground control display shows PLATFORM
LEVEL > 15 DEGREES FAULT and the platform
level controls do not work, the machine will need to
be recovered by trained and authorized personnel
or a qualified service technician.
Platform Overload Indicator Light
Light flashing indicates the
platform is overloaded and no
functions will operate.
Remove weight from the
platform until the light goes off.
Overload Recovery
If the ground controls LCD screen displays
OVERLOAD RECOVERY, the emergency lowering
system has been used while the platform was
overloaded. For information on how to reset this
message, please consult the appropriate Genie
Service Manual.
Part No. 1272823GT
Operating Instructions
Generator (if equipped)
To operate the generator, move the generator
switch. The indicator light will come on and the
engine will continue to run.
Plug a power tool into the power to platform GFCI
outlet.
To turn off the generator, move the generator
switch. The indicator light will turn off.
LCD Screen (if equipped)
The LCD screen displays hour meter, voltage, oil
pressure and coolant temperature. The screen also
displays fault codes and other service information.
Perkins Engine
Machines equipped with Perkins 854F-34T Diesel
engines have a regeneration mode that should run
automatically when needed.
LCD will display REGEN FORCED and WARNING
HIGH EXHAUST SYSTEM TEMP when the
regeneration mode is running. No service required.
ZX-135/70
Operator's Manual
53