Electrical system
Standard load voltage:
13-15 V (dc) at 5000 rpm
Locking torques (N*m)
Screw fixing voltage regulator to electrical component supporting plate 6 ± 20% (4.4 ftlb)
Start up system check
TROUBLESHOOTING
Check the battery condition.
Check that the fuses are in good conditions.
Check the ignition switch.
Check the engine stop switch.
Check the stop light relay.
Check the starter button
Check the start-up relay.
Check the starter motor.
START-UP RELAY AND STOP LIGHTS CHECK
Disconnect all the relay cables.
With a tester (in Ohm meter function) measure the continuity between the power terminals.
- Exact value: infinite resistance.
Power the control contacts (connector) with a 12V battery.
With a tester (in Ohm meter function) measure the continuity between the power terminals.
- Exact value: resistance 0 Ohm.
START BUTTON CHECK
Disconnect the button connector.
With a tester (in ohmmeter function), check the continuity between the contacts in the pressed and
released positions according to the connections.
STARTER MOTOR - CHECK
Remove the starter motor and power it directly with an efficient 12V battery.
If the starter motor does not turn regularly, check brushes and manifold for wear.
ELE SYS - 74
ATLANTIC 300 i.e.

Hide quick links: