ERVER 7048R-C1RT/7048R-C1R User's Manual
I-SGPIO1/2 Headers
Two SGPIO (Serial Link General Pur-
pose Input/Output) headers are pro-
vided on the serverboard. I-SGPIO1
supports onboard I-SATA ports while
I-SGPIO2 supports the S-SATA ports.
See the table on the right for pin
definitions.
Power LED/Speaker
Pins 1-3 of JD1 are used for power
LED indication, and pins 4-7 are for
the speaker. Close pins 4-7 of JD1
to use the speaker connector as an
external speaker. To use it as an on-
board buzzer, please close pins 6-7 of
JD1 with a cap. See the tables on the
right for pin definitions.
I-SGPIO Headers
Pin Definitions
Pin Definition
Pin
Definition
1
NC
2
NC
3
Ground
4
Data
5
Load
6
Ground
7
Clock
8
NC
Note: NC= No Connection
Speaker
PWR LED
Connector
Connector
Pin Settings
Pin Definitions
Pin
Definition
Pin
Definition
Pin 4
P5V
Pin 1
JD1_PIN1
Pin 5
Key
Pin 2
FP_PWR_LED
Pin 6
R_SPKPIN_N
Pin 3
FP_PWR_LED
Pin 7
R_SPKPIN
5-20
5-8

Jumper Settings

Explanation of Jumpers
To modify the operation of the
serverboard, jumpers can be used
to choose between optional settings.
Jumpers create shorts between two
pins to change the function of the
connector. Pin 1 is identified with
a square solder pad on the printed
circuit board. See the diagram at right
for an example of jumping pins 1 and
2. Refer to the serverboard layout
page for jumper locations.
Note: On two-pin jumpers, "Closed"
means the jumper is on and "Open"
means the jumper is off the pins.
CMOS Clear
JBT1 is used to clear CMOS and will also clear any passwords. Instead of pins,
this jumper consists of contact pads to prevent accidentally clearing the contents
of CMOS.
To clear CMOS
1. First power down the system and unplug the power cord(s).
2. With the power disconnected, short the CMOS pads with a metal object such
as a small screwdriver.
3. Remove the screwdriver (or shorting device).
4. Reconnect the power cord(s) and power on the system.
Note: Do not use the PW_ON connector to clear CMOS.
LAN Enable/Disable
JPL1 enables or disables Gigabit LAN ports
1/2 on the X10DRH-C and 10G LAN ports
1/2 on the X10DRH-CT. See the table on the
right for jumper settings. The default setting
is Enabled.
Chapter 5: Advanced Serverboard Setup
3
2
1
Connector
Pins
Jumper
3
2
1
Setting
LAN Enable
Jumper Settings
Jumper Setting Definition
Pins 1-2
Enabled
Pins 2-3
Disabled
5-21