3.3.6
Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure 3-8). All other restrictions and instructions
for the shield termination technique set forth for Method A and B are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.

Figure 3-8 Daisy Chain between Methods A and B

3.3.7
Splicing Signal Wires
Refer to Figure 3-9 for GMA 245R installations, or to
NOTE
Figure 3-9 and
from outside the edge of clamp to the end of the 3 inch max mark.
WARNING
Keep the splice out of the backshell for pin extraction, and outside of the strain relief to
avoid preloading.
Figure 3-9 and
Figure 3-10
wire is spliced, it is located out front of splice along with signal wire going to pin.
Splice part numbers:
•Raychem D-436-36/37/38
•MIL Spec MIL-S-81824/1
This technique may be used with shield termination methods: A.1, A.2, B.1, B.2, C.1 and C.2.
190-01879-11
Rev. 6
Figure 3-10
illustrate that a splice must be made within a 3 inch window
show a two wire splice, but a maximum of three wires can be spliced. If a third
Figure 3-10
for GMA 245 installations.